Solution 2.3 Installation and Operation Manual 35
7.4.2 Table of Clearance Reduction Percentages
Type of shield
Clearances may be reduced
by these percentages
Sides
and rear %
Top %
(ceiling)
Sheet metal, a minimum of 24 gauge
(0.61 mm) in thickness , spaced out at
least 25 mm (1 in)* by non-
combustible spacers
67 50
Ceramic tiles, or equivalent non-
combustible material, on non-
combustible board spaced out at least
25 mm (1 in)* by non-combustible
spacers
50 33
Ceramic tiles, or equivalent non-
combustible material, on non-
combustible board, with a minimum of
24 gauge (0.61 mm) sheet metal
backing spaced out at least 25 mm
(1 in)* by non-combustible spacers
67 50
Brick, spaced out at least 25 mm
(1 in)* by non-combustible spacers
50 N/A
Brick, with a minimum of 24 gauge
(0.61 mm) sheet metal backing,
spaced out at least 25 mm (1 in)* by
non-combustible spacers
67 N/A
* In Canada this space can be 21 mm (7/8 in)